CE Marking Medical Devices

CE Marking Medical Devices

Devices that are intended to be used for medical purposes are likely to be required to be CE marked under the Medical Devices Directive (93/42/EEC, as amended), however it is important to note that not everything found in a hospital or in a healthcare setting will fall within scope. Only devices or accessories of such devices that fulfil a specific definition can be CE marked.

The Directive defines a medical device as any instrument, apparatus, appliance, software, material or other article that is intended to be used for the purposes of (where appropriate) diagnosis, prevention, monitoring, treatment, alleviation or compensation of a disease, or an injury or a handicap. The Directive also covers ‘devices’ used for the investigation, replacement or modification of the anatomy or of a physiological process, and of control of conception. As with the majority of the Directives, there is also a list of exclusions, with two most prominent being the Active Implantable Medical Devices and In-Vitro Diagnostic Medical Devices Directives.

A wide range of devices are covered by the Medical Devices Directive (MDD) and naturally some of the devices are deemed to pose a higher risk than others, for example the hazards associated with surgical tools are likely to be far greater when compared to a hospital bed. Instead of having one size fits all, the Directive deals with the wide range of devices by splitting them into one of the four classes (Classes I, IIa, IIb and III).

Accessories, whilst not being a device by themselves, are intended (by its manufacturer) to be used with a device, for the device to function as intended by the manufacturer. Accessories shall be treated as a device and shall be classified in their own right separately from the device with which they are to be used.

Many of the other ‘Product Directives’ have links to the Medical Devices Directive; predominately related to exclusions. For example, devices covered by the MDD, are excluded from the Low Voltage, ElectroMagnetic Compatibility, Pressure Equipment (Category 1 and SEP only) Directives. The MDD also states that were a relevant hazard exists, devices which are also machines as per the Machinery Directive, shall also comply with the relevant Essential Health & Safety Requirements of the Machinery Directive. The requirement shall only be applied to the extent where they are more specific than the essential requirements set out in the MDD.

Conformity Procedures

The route to conformity is very much dependent upon the classification of the device. Class I devices can be self-declared, where any other class requirements the involvement of a Notified Body. Classification is decided upon establishing the applicable rule within Annex IX of the Medical Devices Directive. From here the route to conformity is explained within Article 11 and the applicable Annex.

For Class I devices (other than custom-made or devices intended for clinical investigations), the conformity assessment procedure is set out in Annex VII and is known as ‘EC Declaration of Conformity.’ The procedure is summarised below:

Medical Devices CE Marking Process

Whilst other Product Legislation requires manufacturers to undertake a risk assessment, the Medical Devices Directive goes further and effectively requires a Risk Management System (RMS) to be implemented. The RMS not only deals with the identification of the initial hazards associated with a device, but also has the procedures for undertaking post market surveillance. Whilst the Directive does not set out a formal procedure, a harmonised European Standard (EN ISO 14971) is available to be used.

Finally, the requirement to register the company with an enforcement authority is unique to the Medical Devices Directive. In the UK, manufacturers would register themselves with the MHRA (at the cost of a small administration charge). Registration is on a per-product-code basis, not necessarily on a per-product basis. Multiple codes may apply where a manufacturer has a wide product portfolio, however the registration form allows this to be done in a single application.

Please always refer to the Directive for the full text and definitions to help understand the application and requirements of the Medical Devices Directive.

How we can help you:

The CE Marking Association have a range of services to assist manufacturers, importers and users of Class I Medical Devices with a range of services, as well as providing advice for the Class IIa & b and Class III Devices too. Here are some of the services on offer:

  • Identification of the Class and Route to Conformity
  • Risk Assessments / Risk Management Files to EN ISO 14971
  • Harmonised Standards Assessments and Testing (including EN 60601-1)
  • Electromagnetic Compatibility (EMC) Testing to EN 60601-1-2
  • Technical Documentation Compilation